{"id":3070,"date":"2015-01-05T18:59:34","date_gmt":"2015-01-06T00:59:34","guid":{"rendered":"http:\/\/benincosa.com\/?p=3070"},"modified":"2015-01-06T10:27:08","modified_gmt":"2015-01-06T16:27:08","slug":"ucs-invicta-iscsi-to-vmware-esx","status":"publish","type":"post","link":"https:\/\/benincosa.com\/?p=3070","title":{"rendered":"UCS Invicta iSCSI to VMware ESX"},"content":{"rendered":"<p>I have a 12TB UCS Invicta appliance in my lab I thought I&#8217;d try out. \u00a0The interface wasn&#8217;t as intuitive as I would have preferred, but the nice thing about it is that its simple and pretty easy to use once you get the feel of it.<\/p>\n<h2>Invicta Configuration<\/h2>\n<h4>Create a LUN<\/h4>\n<p>Navigate to the LUN configuration and click Create LUN on the top. \u00a0I&#8217;m just going to do a 100GB LUN for fun. \u00a0I called my lun3<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-3.56.35-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3071\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-3.56.35-PM.png\" alt=\"Screen Shot 2015-01-05 at 3.56.35 PM\" width=\"1716\" height=\"1154\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h4>Initiator Group Configuration<\/h4>\n<p>I already have an Initiator group I call esx. \u00a0This is all my ESX servers that share the LUNs. \u00a0When I first saw this interface I didn&#8217;t know what to do. \u00a0It turns out that some of the links you can right click on to get details.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.00.53-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3072\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.00.53-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.00.53 PM\" width=\"550\" height=\"478\" \/><\/a><\/p>\n<p>Here I say Add Initiator and will plug in my ESX initiator. \u00a0The problem is, I haven&#8217;t defined on on my ESX server yet. \u00a0So let&#8217;s do that then come back.<\/p>\n<h2>ESX iSCSI configuration<\/h2>\n<p>Clicking on the host inside the Configuration tab, we first click on Storage Adapters. \u00a0Under Add in the top right we can add a new Software iSCSI initiator.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.05.32-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3073\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.05.32-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.05.32 PM\" width=\"1784\" height=\"794\" \/><\/a>Now that we have an iSCSI Adapter, we need to connect it to a physical interface. \u00a0Usually with iSCSI we have a separate vmkernel interface that we can use.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.06.54-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3079\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.06.54-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.06.54 PM\" width=\"1596\" height=\"1192\" \/><\/a><\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.10-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3074\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.10-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.07.10 PM\" width=\"1596\" height=\"1172\" \/><\/a><\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.26-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3075\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.26-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.07.26 PM\" width=\"1600\" height=\"1186\" \/><\/a><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.44-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3076\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.44-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.07.44 PM\" width=\"1580\" height=\"1176\" \/><\/a><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.54-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3077\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.07.54-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.07.54 PM\" width=\"1576\" height=\"1148\" \/><\/a>\u00a0After you do this you typically create another one for iSCSI-B to give it network redundancy. \u00a0We&#8217;ll omit this here as we&#8217;re just showing the basic idea.<\/p>\n<p>Now, go back to the Storage Adapters menu and we&#8217;ll attach this interface to our software initiator.<\/p>\n<p>Click on the iSCSI initiator and select properties on the detail screen on the bottom. \u00a0On the network configuration tab, select the iSCSI adapter.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.15.07-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3080\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.15.07-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.15.07 PM\" width=\"1128\" height=\"1200\" \/><\/a><\/p>\n<p>In the dynamic discovery tab, we add the UCS Invicta:<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-06-at-8.24.27-AM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3093\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-06-at-8.24.27-AM.png\" alt=\"Screen Shot 2015-01-06 at 8.24.27 AM\" width=\"1124\" height=\"1190\" \/><\/a><\/p>\n<p>Closing this window, it will rescan the devices and you&#8217;ll be disappointed to see that the Invicta LUN we created will not be shown. \u00a0This is because we didn&#8217;t add the iSCSI LUN to our initiator group.<\/p>\n<p>At this point as a quick sanity check, I usually ssh into the box at this point and make sure I can ping the UCS Invicta appliance. \u00a0If that doesn&#8217;t work then you&#8217;re not going to get much farther.<\/p>\n<h2>Finishing off the Connection<\/h2>\n<p>Now we go back to the Invicta Appliance and add our LUN into the initiator group. \u00a0Right click on the initiator group you have (or create a new one) and then select &#8216;Add Initiator&#8217;<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.19.38-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3081\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.19.38-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.19.38 PM\" width=\"956\" height=\"246\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>The next screen you fill in the Initiator that you see on the vCenter screen under Storage Adapters. \u00a0Mine was iqn.1998-01.com.vmware:esx04-1e63ab9d<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.20.10-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3082\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.20.10-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.20.10 PM\" width=\"1070\" height=\"642\" \/><\/a>After adding you should see it in the list of initiators.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.20.36-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3083\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.20.36-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.20.36 PM\" width=\"714\" height=\"94\" \/><\/a><\/p>\n<p>Right clicking on the Initiator group again will allow us to add the LUN to this group.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.24.37-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3084\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.24.37-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.24.37 PM\" width=\"430\" height=\"228\" \/><\/a><\/p>\n<p>On this screen we drag and drop the LUN from the bottom to the top. \u00a0This to me is why the interface isn&#8217;t that intuitive. \u00a0Sometimes you right click, sometimes you drag and drop. \u00a0Once you drop it in place you can pick the LUN ID.<\/p>\n<p><a href=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.26.47-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-3085\" src=\"http:\/\/benincosa.com\/wp-content\/uploads\/2015\/01\/Screen-Shot-2015-01-05-at-4.26.47-PM.png\" alt=\"Screen Shot 2015-01-05 at 4.26.47 PM\" width=\"1006\" height=\"514\" \/><\/a>Going back to the vCenter console we can now rescan the interfaces.<\/p>\n<p>Right click the iSCSI software adapter and do a rescan. \u00a0Your LUNs should be up now!<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>I have a 12TB UCS Invicta appliance in my lab I thought I&#8217;d try out. \u00a0The interface wasn&#8217;t as intuitive as I would have preferred, but the nice thing about it is that its simple and pretty easy to use once you get the feel of it. Invicta Configuration Create a LUN Navigate to the&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[570,992,39],"tags":[625,571,981],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/posts\/3070"}],"collection":[{"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/benincosa.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3070"}],"version-history":[{"count":3,"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/posts\/3070\/revisions"}],"predecessor-version":[{"id":3095,"href":"https:\/\/benincosa.com\/index.php?rest_route=\/wp\/v2\/posts\/3070\/revisions\/3095"}],"wp:attachment":[{"href":"https:\/\/benincosa.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/benincosa.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/benincosa.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}